Riverstone Networks RS 32000 Switch Router Getting Started Guide 3-7
Hardware Installation Installing the Hardware
.
Figure 3-3 Installing a DC power supply
5. Attach wires to the terminals on the front of the unit. To attach a wire, remove the terminal nut, place
the cable’s wiring lug over the terminal stud, replace and tighten the terminal nut.
6. Connect the safety ground wire to a reliable earth ground.
7. Connect the DC input wiring to the DC power source.
Note If power to the DC power supply is connected incorrectly (reversed), the power
supply emits an audible alarm.