Riverstone Networks RS 32000 Switch Router Getting Started Guide 3-9
Hardware Installation Installing the Hardware
3.3.5 Installing a Redundant Switch Fabric Module
On the RS 32000, the primary Switch Fabric module is installed in the chassis at the factory. If ordered, an optional
redundant Switch Fabric module is shipped separately from the RS 32000 chassis.
To install a Switch Fabric module perform the following steps:
1. Open the Switch Fabric door, as shown in Figure 3-4.
Figure 3-4 Opening the Switch Fabric door
2. Open the ejectors on both sides of the Switch Fabric module you are installing.
3. Position the Switch Fabric module into the available slot.
4. Slide the Switch Fabric module all the way into the slot, firmly but gently pressing to ensure that the
pins on the back of the module are completely seated in the backplane.
5. To lock the module into the slot, close the ejectors.